Q: 1
The peak write bandwidth for an application is 10MB / S, with an average write latency of 200KB / s and an average write IO size of 4KB (bandwidth utilization of 70%). If you need to use OceanStor V3 storage array to implement data disaster recovery and set it as asynchronous replication mode, you need the minimum network-wide bandwidth of which of the following?
Options
Q: 2
In a synchronous replication scenario, an application's peak write throughput is 16 MB/s, average write throughput is 500 KB/s, average write 1/0 size is 8 KB, private information overhead is about 11%, and the FC network bandwidth utilization rate is 70%. The throughput of the disaster recovery network must be at least ( ).
Options
Q: 3
Customers purchased 3 RH228H v2 hosts (with LPE12002-AP_8G HBA with 2 FC ports), 2 Oceanstor VIS6600T (a total of eight four-port 8G FC interface card, two 4-port 1GE interface card, two 8-port 1GE switch module), two Huawei OCeanStor S6800T, and 2 Brocade 300 switches to build VIS6600T 4-node cluster and pass two S6800Ts. The VIS600T cluster is mirrored. Each of the three hosts needs a standard dual-switch redundancy network connected to the VIS6600T4 node. Each Brocade 300 Fiber Channel switches need to use which number of FC ports?
Options
Q: 4
In the N8500 (V200R001) clustered NAS system, when the created file system is used for applications accessing large files sequentially, which of the following is correct?
Options
Q: 5
A company IT system administrator is responsible for the configuration management of OceanStor V3 storage system in Huawei. In the scenario described, which of the following is the correct configuration of Smart Migration:
Options
Q: 6
In the Huawei OceanStor storage array, the write cache high watermark is 80 and the low watermark is 20, and the service type is multiple-order small IO. To achieve better performance, it is advisable to adjust the water marks in which way?
Options
Q: 7
There are many services in the 8500 clustered NAS system that support system functions, such as NFS and CIFS basic service groups. Each service group is a collection of resources, each resource has an agent responsible for managing these resources, the availability of these resources directly or indirectly affect the status of the service. Which of the following is not an NFS service group resource agent?
Options
Q: 8
Info Replication supports copying the data at the same time using the home directory, extended attributes, ACL (access control list), WORM, and CIFS. NFS configuration information is also copied to the slave. When a disaster occurs, the master and slave stations can quickly take over after the switchover.
Options
Q: 9
Customers need to migrate 10TB service data from a manufacturer's mid-tier storage to Huawei OceanStor S5600T (V100R005), storage array, A total of 120 LUN carrying oracle, ESXI virtual machine business plans to use VIS6000T local image data migration. Based on this, which of the following is incorrect?
Options
Q: 10
Which of the following about the multi-channel usage of Huawei OceanStor 9000 to SMB3 is correct? (multiple choice)
Options
Q: 11
Which of the following statement regarding the Huawei disaster recovery solution on the implementation of disaster recovery exercise is wrong?
Options
Q: 12
A customer needs 60TB of capacity. If you use 600G 15K SAS disks using Oceanstot V3 storage, create a RAID 5pool (8D + 1P), with low hot standby strategy, please estimate at least how many hard drives are needed? (Choose the closest value, assuming you do not consider the need for data protection space)
Options
Q: 13
Which of the following are false about OceanStor V3 LUN copy and clone: (multiple choice)
Options
Q: 14
On the command line of the N8500 (V200R001) clustered NAS system, you run the NFS> share add / vx / xs-cmfs 100.43.13.210 command. One system that is used NFS sharing has IP address 100.43.13.11. If the client operating system is Suse Linux, which of the following access to the description of the file system is correct: (multiple choice)
Options
Q: 15
VMware cluster high availability technology enables proxies and Vcenter servers on each physical virtualization host to perform proxy communications. Vcenter retry and arbitration can be used to determine if there is a failure of this host
Options
Q: 16
In a client OceanStor V3 storage array, the engineer examines the log information, the search found that power failure time point has the following: "1 & 1 or 2 & 3 -" not exist ", you can determine the reason for the system failure to start is not inserted into the safe disk
Options
Q: 17
Which if the following is correct regarding the Huawei Oceanstor unified storage system multi-planar system design?
Options
Q: 18
In a Huawei N8500 cluster system VCS Error information is stored in which of the following log files? (Multiple choice)
Options
Q: 19
In the Huawei OceanStor system, the size of the file system block is a measure of the size of the accessed file system block. The size of the block is designed according to the size of the data block. Different size of the file system block selects the corresponding file system block, according to the size of the data block. If the business scenario is the media, for large file archiving or stagger I / O backup scenarios, it is recommended to choose the default 64KB disk block size.
Options
Q: 20
Which of the following are correct regarding a Storage Array RAID 2.0 Typical Application Performance Tuning? (multiple choice)
Options
Question 1 of 20