Free D-PE-OE-01 Practice Test Questions and Answers (2026) Practice Questions

Free preview: 20 questions.

Dell EMC D PE OE 01.pdf

View Mode
Q: 1
In order to Improve efficiency of the Data Center, the IT department has been tasked with auditing the health and performance, including any sensor alerts, for all Dell servers from the past quarter. Which two basic actions must be taken on the servers in order to obtain the requested information?
Options
Q: 2
A Dell PowerEdge server reports intermittent hardware alerts and occasional system instability. An administrator needs to Identify and resolve the underlying hardware Issue with minimal disruption to services. Which action should the administrator take first to troubleshoot the hardware problem?
Options
Q: 3
On a Dell PowerEdge server equipped with NVIDIA GPUs, one of the installed GPUs shows a continuous Increase in ECC Correctable Errors whenever the system is under load. Running dcgmi diag -r 3 returns PASS for all diagnostic tests, and a full GPU memory BIST detects no memory cell faults. The IDRAC System Event Log repeatedly reports: ’ Correctable Memory Warning increased” for the same GPU. The system appears healthy, and no PCIe or XID fatal errors are recorded. What action should be taken first?
Options
Q: 4
A Dell PowerEdge server has Temperature Alert Configuration set up in iDRAC. A Test Event was executed, and email alerts appeared to be delivered successfully. However, a few days later, the server unexpectedly rebooted. Upon inspection, CPU temperatures had exceeded the configured threshold. What is a possible reason IDRAC failed to alert the administrator about the high temperature?
Options
Q: 5
An Administrator wants to change the PSU configuration In such a way that it can be redundant and can set PSU1 as the primary. What redundancy policy should the administrator select?
Options
Q: 6
You are assisting an administrator, who Is working on a PowerEdge R670. They are trying to connect to iDRAC using iDRAC Direct but cannot make a connection. The LED status indicators are: the wrench/spanner LED on the front right is off, the system ID LED on the front right is blinking blue, and the power LED on the front right is amber. What action should be taken to establish connectivity?
Options
Q: 7
A technician In a data center must update the firmware on a server that has no network connectivity. Which two tools must the technician use together to update the BIOS, iDRAC, and lifecycle Controller firmware?
Options
Q: 8
A Dell PowerEdge server is experiencing intermittent hardware alerts, and the operating system is occasionally unresponsive. An administrator needs to diagnose and troubleshoot the hardware issue efficiently. Which three tools can be used to troubleshoot hardware issues on a Dell PowerEdge server?
Options
Q: 9
A company with a 17G PowerEdge Server model requires these features: Essential System Management Features; Core Features, Automation, Virtual and Security Enhancements; Enterprise Features with added telemetry, thermal management, support for accelerators (GPU and DPU), and advanced Air and Liquid Cooling. Which iDRAC license is the minimum required to meet these requirements?
Options
Q: 10
A Dell PowerEdge server becomes unresponsive at the operating system level, but an administrator still needs to check hardware health, review system event logs, and diagnose potential component failures remotely. Which two tools can be used to perform these tasks independently of the operating system?
Options
Question 1 of 20

Premium Access Includes

  • Quiz Simulator
  • Exam Mode
  • Progress Tracking
  • Question Saving
  • Flash Cards
  • Drag & Drops
  • 3 Months Access
  • PDF Downloads
Get Premium Access
Scroll to Top

FLASH OFFER

Days
Hours
Minutes
Seconds

avail 10% DISCOUNT on YOUR PURCHASE