Dell D-VXR-DS-01 Real Exam Questions [2026 Update]
What Users Are Saying:
The shift from D-VXR-DS-00 to D-VXR-DS-01 restructured the entire exam framework – and that restructuring tells a candidate exactly what Dell thinks a VxRail design professional should be. The previous exam (D-VXR-DS-00) organised its questions around product components: what are the physical elements of a VxRail cluster, what are the node types, what tools exist. The v2 exam (D-VXR-DS-01) organises its questions around the stages of a design project: how do you gather and analyse requirements, how do you translate requirements into a design, and how do you validate and present that design after it is complete. This is a more sophisticated test of professional capability – and it front-loads the most important insight: sixty percent of the exam is in the Design domain. A candidate who splits study time evenly across all three domains and assumes balanced question distribution will be underprepared for the weight of the design phase questions.
The design tools are the most precisely tested category within the Design domain – and the three primary tools have distinct roles that the exam tests through scenario-matching questions. Live Optics is a data collection and analysis tool deployed in a customer’s existing environment to capture current workload data – it inventories physical infrastructure, collects performance metrics (CPU utilisation, memory usage, storage IOPS and throughput, network utilisation) over a defined observation period, and produces a workload profile that a VxRail designer uses to size the new HCI environment. VxRail Sizer is the sizing and configuration tool – it takes workload requirements (from Live Optics output or from manually entered requirements) and produces VxRail node configurations and cluster sizes that satisfy the workload while respecting vSAN capacity and availability constraints. EIPT (Enterprise Infrastructure Planning Tool) is the environmental and physical planning tool – it calculates power, cooling, rack space, and weight requirements for the designed VxRail solution. The exam tests these three tools in the correct sequence: Live Optics first (gather data), then VxRail Sizer (design the cluster), then EIPT (plan the physical environment). Candidates who confuse which tool performs which function – or who apply them in the wrong sequence – lose points on every tool scenario question.
The Post Design domain (20%) is the area most candidates under-study – and it is where professionals who have real-world VxRail design experience can most efficiently earn points while candidates who studied only technical content fall behind. Post Design tests three capabilities that are specifically about communicating, validating, and configuring a completed design rather than creating it: producing design documentation that communicates architectural decisions clearly to both technical and non-technical stakeholders, validating the design against the original requirements (checking that the configuration generated by the Sizer actually satisfies every stated requirement – storage, compute, network, and environmental), and using the VxRail Configuration Portal to configure the designed solution for ordering. The VxRail Configuration Portal is the step that bridges the design output and the physical equipment order – it validates that the designed node configurations are orderable and within Dell’s supported configuration rules.
Exam Snapshot
| Field | Details |
| Exam Code | D-VXR-DS-01 |
| Full Name | Dell VxRail Design v2 |
| Vendor | Dell Technologies |
| Program | Dell Technologies Proven Professional |
| Format | Proctored exam (Pearson VUE) |
| Passing Score | Not published by Dell |
| Cost | USD $230 |
| Replaces | D-VXR-DS-00 (VxRail Design v1) |
| Languages | English, French |
What VxRail Is
Dell VxRail is a hyper-converged infrastructure (HCI) appliance co-engineered by Dell and VMware. Each VxRail node integrates Dell PowerEdge server hardware with VMware vSAN for distributed software-defined storage, VMware vSphere for compute virtualisation, and VMware vCenter for management – all in a single appliance chassis. VxRail clusters start at a minimum of 3 nodes (4 for some vSAN configurations) and scale by adding nodes, with each added node contributing its compute, memory, and storage capacity to the cluster pool. VxRail is fully managed through the VxRail Manager plugin for vCenter, which streamlines cluster lifecycle operations – initial deployment, node addition, software upgrades – into guided workflows.
Domain 1: Gathering Requirements (20%)
Workload assessment: The design process begins with understanding the customer’s current and projected workloads. A workload assessment captures: application types (VM-based workloads, databases, VDI, dev/test), performance requirements (IOPS targets, throughput requirements, latency sensitivity), availability requirements (desired cluster availability, tolerated failure scenarios), and growth projections (expected capacity and performance growth over a 3-5 year horizon).
Using Live Optics for data collection:
Live Optics is deployed as a lightweight agent in the customer’s existing environment – it inventories all physical and virtual infrastructure, and for a configurable collection window (typically 7-30 days) it collects performance telemetry:
CPU utilisation: Peak and average CPU utilisation across all hosts – identifying compute headroom requirements for the new cluster.
Memory utilisation: Peak and average memory usage – identifying total memory required across the cluster, including vSphere overhead.
Storage performance: IOPS and throughput at the storage level – identifying vSAN performance requirements.
Network utilisation: Current network traffic patterns – identifying network capacity requirements for vSAN replication traffic and VM network traffic.
The Live Optics data collection period should capture peak workload periods (month-end, quarter-end, or seasonal peaks relevant to the customer’s business) to ensure the design is sized for actual peak demand rather than average demand.
Understanding customer requirements beyond performance:
Beyond raw performance data from Live Optics, the requirements gathering phase captures:
RPO/RTO requirements: What data protection the workloads require – Recovery Point Objective (maximum tolerable data loss) and Recovery Time Objective (maximum tolerable downtime). These requirements drive data protection design decisions (vSAN stretched cluster, replication, backup).
Compliance and regulatory requirements: Data residency constraints, encryption-at-rest requirements, or audit logging requirements that affect the VxRail configuration.
Network architecture requirements: Existing network infrastructure (switch types, available ports, VLANs) and network design requirements (jumbo frames, dedicated vSAN VMkernel networks, management network segregation).
Physical environment constraints: Rack space availability, power capacity, cooling capacity, and weight limits – gathered through site assessment and later validated using EIPT.
Domain 2: Design (~60%)
Using VxRail Sizer:
VxRail Sizer is the primary configuration tool that translates workload requirements into specific VxRail node configurations and cluster sizes. Key Sizer inputs:
Workload profile: CPU, memory, and storage requirements – either imported from a Live Optics report or entered manually. The Sizer uses these inputs to calculate the minimum cluster size needed to satisfy the workload while maintaining vSAN availability (preserving space for the slack space required by vSAN’s rebuild operations and maintaining the configured FTT – Failures to Tolerate).
Node type selection: The Sizer matches requirements to available VxRail node types (V-series, E-series, P-series, D-series, S-series nodes – each targeting different workload profiles from all-flash high-performance to large-capacity hybrid). The exam tests node type selection as a scenario-matching exercise: given a described workload (high IOPS database, high-capacity archive, GPU compute), identify which VxRail node series is appropriate.
Cluster size output: The Sizer produces a recommended cluster node count and configuration – showing how many nodes of the specified type are needed to satisfy the workload while meeting the FTT (Failures to Tolerate) constraint, which determines the minimum node count (FTT=1 requires minimum 3 nodes for RAID-1, 4 nodes for RAID-5 with Erasure Coding).
vSAN capacity and availability design:
FTT and cluster sizing: vSAN’s Failures to Tolerate setting determines how many simultaneous drive or host failures the cluster can sustain while remaining operational. FTT=1 with RAID-1 (mirroring) requires a minimum of 3 nodes and consumes 2x storage capacity. FTT=1 with RAID-5 (erasure coding) requires a minimum of 4 nodes and consumes 1.33x storage capacity – more capacity-efficient than RAID-1 but requires more nodes for the minimum. FTT=2 with RAID-6 requires a minimum of 6 nodes. The exam tests FTT selection as a design decision driven by the customer’s stated availability requirement.
Slack space: vSAN requires a minimum of 25% free space on each vSAN datastore for rebuild operations when a node fails – this slack space is not available for VM storage and must be accounted for in capacity planning. VxRail Sizer includes slack space in its capacity calculations automatically, but candidates must understand why the usable capacity is less than the raw drive capacity × node count.
Network design for VxRail:
VxRail management network: The management network carries VxRail Manager, vCenter, ESXi management, and IPMI traffic. It must be a dedicated VLAN with IP addresses for each node’s management interface, vCenter, and VxRail Manager.
vSAN VMkernel network: vSAN traffic (between nodes for distributed storage reads/writes and rebuild operations) requires a dedicated VMkernel port group on a high-bandwidth network. Dell recommends a minimum 10GbE network for vSAN traffic; 25GbE is recommended for performance-sensitive workloads. Jumbo frames (MTU 9000) are required for the vSAN network.
vMotion network: VMware vMotion (live virtual machine migration between hosts) requires a dedicated VMkernel network – it must have sufficient bandwidth to complete migrations within the vMotion timeout without affecting production VM traffic.
VM network: Production VM traffic requires one or more VM port groups – VLAN configuration on the upstream switches must match the VxRail cluster’s VM network VLAN assignments.
Designing for specific VxRail configurations:
2-node cluster design: The minimum VxRail cluster for remote/branch office deployments. 2-node clusters require a vSAN Witness – a lightweight virtual appliance deployed off-cluster (typically in a central data centre or cloud) that provides the third vote for vSAN quorum. Without the Witness, a 2-node cluster cannot tolerate a single node failure (neither node can establish quorum independently).
Stretch cluster design: A VxRail stretched cluster spans two data centre sites – half the nodes at each site, with a vSAN Witness at a third site. The stretched cluster provides active-active VM access from both sites, with vSAN mirroring data between sites synchronously. Stretch cluster design constraints: maximum 5ms one-way latency between sites (10ms RTT), minimum 10Gbps bandwidth between sites, and the vSAN Witness must have network connectivity to both sites.
Dynamic Node design: VxRail Dynamic Node is a compute-only node variant – it adds compute and memory capacity to a cluster without adding storage. Dynamic Nodes are appropriate for compute-intensive workloads (VDI, AI inference) where compute capacity is the bottleneck rather than storage capacity.
vSAN ESA design: vSAN Express Storage Architecture (ESA) is the newer vSAN storage architecture available on supported VxRail node types – it uses NVMe drives exclusively and provides better performance and higher compression ratios than the original vSAN OSA (Original Storage Architecture). ESA design considerations include: all drives must be NVMe (no hybrid or SAS options), ESA requires a minimum 3-node cluster for FTT=1, and ESA’s compression is always-on (unlike OSA where deduplication/compression is optional per datastore).
Using VxRail Configuration Tools:
VxRail Configuration Portal: After the Sizer produces a node configuration, the VxRail Configuration Portal is used to create the formal solution configuration – selecting specific PowerEdge server models, drive configurations, memory options, and network adapters that match the Sizer output. The Configuration Portal validates that the selected configuration is within Dell’s supported specifications and is orderable. The output of the Configuration Portal is the formal bill of materials for the VxRail solution.
Enterprise Infrastructure Planning Tool (EIPT): EIPT calculates the physical and environmental requirements for the designed VxRail solution – generating rack layout diagrams showing node placement, calculating total power consumption (in watts and amps), cooling requirements (in BTUs/hour or kW), and rack weight. EIPT outputs are used to validate that the customer’s data centre has sufficient rack space, power circuits, and cooling capacity to support the designed solution.
Domain 3: Post Design (20%)
Creating design documentation:
Professional design documentation for a VxRail solution includes: an executive summary (high-level description of the solution and its business value, suitable for non-technical stakeholders), a technical design overview (the architecture and key decisions – node types, cluster size, network design, availability configuration), a detailed configuration specification (the exact node and network configuration from the Configuration Portal), and physical design (the rack layout and environmental data from EIPT). The exam tests design documentation as a professional deliverable that must communicate clearly to both technical and non-technical audiences.
Validating the design:
Design validation confirms that the Sizer output and Configuration Portal selection actually satisfy every stated requirement gathered in Domain 1:
Capacity validation: Confirming that the designed cluster provides sufficient usable storage capacity after accounting for vSAN overhead (FTT consumption), slack space (25% minimum), and the deduplication/compression savings ratio used in the Sizer calculation.
Performance validation: Confirming that the selected node types and cluster size provide sufficient IOPS and throughput to meet the performance requirements – comparing the Sizer’s estimated performance output against the requirements gathered by Live Optics.
Availability validation: Confirming that the FTT configuration and cluster size satisfy the customer’s availability requirements – verifying that the cluster can tolerate the stated number of node failures without data loss.
Environmental validation: Confirming that the EIPT output (power, cooling, space) is within the customer’s data centre physical capacity.
Presenting the design:
Design presentation to the customer includes explaining the architectural decisions – why a specific node type was chosen, why a specific FTT was configured, how the network design satisfies the customer’s existing infrastructure – in terms that align with the customer’s business requirements and priorities. The exam tests presentation skills as the ability to frame technical decisions in terms of the business outcomes (availability, performance, scalability) rather than technical specifications alone.
Using the VxRail Configuration Portal for post-design tasks:
After customer approval of the design, the Configuration Portal’s output serves as the purchasing specification. Operators use the Portal to generate a formal quote, verify component availability, and confirm that the configured solution meets Dell’s current supportability requirements before order submission.
5 Study Tips for Dell D-VXR-DS-01
- Spend the majority of your study time on the Design domain (approximately 60% of exam weight) – focus especially on VxRail Sizer inputs and outputs, FTT selection and minimum node count requirements, and the three design tool roles (Live Optics → data collection, VxRail Sizer → cluster sizing, EIPT → environmental planning).
- Study the three design tool roles as a sequential workflow – Live Optics gathers workload data, VxRail Sizer uses that data to produce a configuration, EIPT validates the physical environment for that configuration. Know which tool performs which function.
- Study the three special cluster configurations (2-node + Witness, Stretch Cluster, Dynamic Node) as scenario-matching topics – know the design constraints for each (2-node: Witness required; Stretch: 5ms one-way latency limit, 10Gbps minimum WAN; Dynamic Node: compute-only, no storage added).
- Study vSAN slack space and FTT capacity consumption – know that FTT=1 RAID-1 requires 2x storage capacity overhead, FTT=1 RAID-5 requires 1.33x, and that 25% slack space is required on top of the FTT overhead for a production-ready cluster.
- Practice with Cert Empire’s D-VXR-DS-01 exam questions covering all three domains at design tool role identification, FTT configuration scenario-matching, stretch cluster constraint knowledge, and post-design validation depth.
Best Study Resources
- Cert Empire D-VXR-DS-01 exam questions PDF and practice simulator (October 2026 edition).
- Dell official D-VXR-DS-01 exam page (learning.dell.com – search “D-VXR-DS-01”).
- VxRail 8.0.XXX Design course (Dell learning portal).
- Dell VxRail Sizer tool (available through Dell partner portal).
- Dell Live Optics documentation and training (liveoptics.com).
- Enterprise Infrastructure Planning Tool (EIPT) guide (Dell partner resources).
Why Candidates Choose Cert Empire for Dell D-VXR-DS-01 Preparation
Free Practice Tests
Sample our D-VXR-DS-01 questions before purchasing. Test your design tool role knowledge, vSAN FTT scenario-matching skills, and stretch cluster constraint understanding before committing.
Regular Updates
Our D-VXR-DS-01 question bank is reviewed against the current v2 exam outline (confirmed October 2026) and updated as Dell releases new VxRail design guidance.
Free Exam Guides
Every purchase includes our free D-VXR-DS-01 exam guide covering all three domain areas, the design tool workflow reference, the FTT minimum node count table, the cluster type comparison guide, and a structured study plan.
PDF Exam Questions – Study Anywhere, Anytime
Download your D-VXR-DS-01 questions instantly after purchase. Study on any device or print the PDF. No login required after download, no expiry on the file.
24/7 Chat Support
Available at any hour for questions about your materials, your order, or specific VxRail Design concepts – including vSAN ESA vs. OSA design differences, EIPT outputs and their use in validation, and 2-node cluster Witness deployment requirements.
3 Months of Unlimited Access
Three full months of unlimited access to the D-VXR-DS-01 question bank and simulator. Revisit design scenario questions, FTT and capacity planning topics, and post-design documentation questions as many times as needed.
Official Vendor Resources – Learn from the Source
Every solution in our D-VXR-DS-01 question bank links directly to the relevant official Dell documentation – the VxRail Design guide, Sizer documentation, EIPT user guide, or the specific Dell VxRail technical reference behind the answer.
Deep Knowledge – Every Answer, Every Option, Fully Explained
Every D-VXR-DS-01 question includes a complete explanation covering not just why the correct design tool, node type, or FTT configuration is right, but precisely why each incorrect option fails – whether it applies EIPT for workload sizing (where VxRail Sizer is correct), selects FTT=1 RAID-5 for a 3-node cluster (which requires minimum 4 nodes), or omits the vSAN Witness from a 2-node cluster design. Each explanation references the specific VxRail design documentation behind the answer.
Interactive Practice Simulator – Think Like the Exam
Our simulator presents VxRail design scenarios exactly as the real D-VXR-DS-01 exam does – describing a customer requirement (a workload profile, a physical constraint, a DR objective) and testing which tool, node configuration, or design decision correctly addresses it. Per-question feedback explains the full VxRail design reasoning behind every correct and incorrect option.
Backed by a Full Money-Back Guarantee
If our D-VXR-DS-01 exam questions do not help you pass, you receive a full refund – no questions asked, no conditions.
FAQ’s
What is the Dell D-VXR-DS-01 certification?
D-VXR-DS-01 is the Dell VxRail Design v2 exam – part of the Dell Technologies Proven Professional program. It validates the ability to design VxRail HCI solutions, covering requirements gathering with Live Optics, cluster sizing with VxRail Sizer, environmental planning with EIPT, network and availability design, special cluster configurations (2-node, stretch, Dynamic Node), and post-design validation and documentation.
What changed from D-VXR-DS-00 to D-VXR-DS-01?
The v2 exam restructures the domain framework from product-component topics to design-project stages: Gathering Requirements (20%), Design (~60%), and Post Design (20%). The v1 exam organised questions around physical components, deployment planning, configuration tools, and specific configurations. The v2 exam tests the full design lifecycle rather than individual component knowledge.
What are the three design tools used in VxRail design and what does each do?
Live Optics is deployed in the customer’s environment to collect current workload performance data – CPU, memory, storage IOPS/throughput, and network utilisation over an observation period. VxRail Sizer takes workload requirements (from Live Optics or manual input) and produces a recommended node type, node count, and cluster configuration that satisfies the requirements. EIPT (Enterprise Infrastructure Planning Tool) calculates the physical environmental requirements of the designed solution – power, cooling, rack space, and weight.
What is the minimum node count for FTT=1 RAID-1 versus FTT=1 RAID-5 in vSAN?
FTT=1 with RAID-1 (mirroring) requires a minimum of 3 nodes. FTT=1 with RAID-5 (erasure coding) requires a minimum of 4 nodes. RAID-5 is more capacity-efficient (1.33x overhead vs. 2x for RAID-1) but requires one additional node for the minimum cluster size.
What is a vSAN Witness and when is it required?
A vSAN Witness is a lightweight virtual appliance deployed off-cluster that provides the third vote for vSAN quorum arbitration. It is required for 2-node VxRail clusters – without the Witness, neither node can establish a quorum majority independently, so a single node failure would make the entire cluster unavailable. It is also required for VxRail stretch clusters (as the third-site arbiter).
What is the maximum latency allowed in a VxRail stretch cluster design?
A VxRail stretched cluster requires a maximum of 5ms one-way latency (10ms round-trip) between the two sites. This constraint ensures vSAN synchronous mirroring between sites completes within the write latency tolerance of production workloads.
What does the VxRail Configuration Portal do in the post-design phase?
The VxRail Configuration Portal is used after the VxRail Sizer produces a configuration to formalise the solution into an orderable bill of materials – selecting specific PowerEdge models, drive types, memory, and network adapters, validating the configuration against Dell’s supported specifications, and generating the formal quote and purchase specification for the designed cluster.
Related Certifications Worth Exploring
VxRail Design professionals building a broader VxRail credential portfolio will find the Dell D-VXR-OE-23 (VxRail Operate 2023) exam questions page covers the operational companion credential – cluster administration, system monitoring, performance optimization, lifecycle management, and troubleshooting – which complements the infrastructure design knowledge that D-VXR-DS-01 validates. For those strengthening their cloud infrastructure and virtualization expertise alongside VxRail HCI deployments, the Dell D-CIS-FN-01 (Cloud Infrastructure and Services Foundations) exam questions page covers cloud architecture, virtualization fundamentals, storage infrastructure, networking, and data protection concepts that support the design and management of hyperconverged enterprise environments.