Q: 1
A NetApp AFF node in a four-node cluster has a single FC port on one node, which Is used for legacy tape
backup. Tape is no longer needed, and the port is disconnected and modified for reuse in the FCP SAN.
Based on this change, which command will verify that the port is usable?
Options
Discussion
No comments yet. Be the first to comment.
Be respectful. No spam.
Q: 2
When using tagged VLANs on Cisco Nexus switches for NVMe over TCP, which two changes must be made to
enable jumbo frames? (Choose two.)
Options
Discussion
No comments yet. Be the first to comment.
Be respectful. No spam.
Q: 3
A site survey has been conducted for an installation of a switchless HA pair with two NetApp DS224C shelves
in the customer's already populated rack.
Which of the following two need to be verified to ensure a successful deployment? (Choose two.)
Options
Discussion
No comments yet. Be the first to comment.
Be respectful. No spam.
Q: 4
You are planning a NetApp SAN environment for a large financial services customer. The customer has two
data centers in different geographic locations and requires that all critical data be mirrored synchronously
between sites for disaster recovery purposes. During the assessment phase, you discover that the WAN link
between data centers has 500 ms latency and 50 Mbps bandwidth, but the customer's SAN applications
require sub-100 ms round-trip response times.
Which of the following represents the best approach to address this constraint?
Options
Discussion
No comments yet. Be the first to comment.
Be respectful. No spam.
Q: 5
A customer wants to enable CHAP authentication on their iSCSI sessions.
Which command should be used to set up the appropriate security policies and passwords?
Options
Discussion
No comments yet. Be the first to comment.
Be respectful. No spam.
Q: 6
An administrator is troubleshooting a SAN network issue where the NVMe/TCP LIF keeps disconnecting.
Which command helps the administrator investigate this issue?
Options
Discussion
No comments yet. Be the first to comment.
Be respectful. No spam.
Q: 7
A customer requires multiple SAN and NAS protocols on a NetApp AFF cluster. The cluster must concurrently
serve a namespace over NVMe/FC, a LUN over FCP, a LUN over iSCSI, and an NFS export.
Based on these requirements, what is the minimum data SVM count that is required?
Options
Discussion
No comments yet. Be the first to comment.
Be respectful. No spam.
Q: 8
A storage engineer is required to provide NetApp site design documentation to show that the NetApp ONTAP
SAN solution was delivered as intended.
Which NetApp tool can the storage engineer use to automate the creation of a difference report?
Options
Discussion
No comments yet. Be the first to comment.
Be respectful. No spam.
Q: 9
You are assessing a customer's environment for a new NetApp ONTAP SAN deployment. The customer has a
large legacy SAN infrastructure with FC switches and older host HBAs. During the assessment phase, you
need to verify network bandwidth requirements and compatibility before recommending a solution. Which of
the following assessment activities are essential to perform during the planning phase?
Options
Discussion
No comments yet. Be the first to comment.
Be respectful. No spam.
Q: 10
An engineer is troubleshooting FC connectivity issues on a customer's system and sees the following output
from the network fcp adapter show command:
According to the output, what is the domain ID of the switch that is connected to port 2a of node n2?
According to the output, what is the domain ID of the switch that is connected to port 2a of node n2?Options
Discussion
No comments yet. Be the first to comment.
Be respectful. No spam.